Hello !
I am trying to Linearise one of my model and notices by selecting Open Loop Input or Input Pertubation the input signal when connected to scope displays the same value !
i.e my default Duty is 0.6 and when specifified Sine stream signal with 0.1 amplitude getting waveform with peaks 0.7 and 0.5 . But when changed the signal to Open Loop Input getting the same values. ?
From the help file what I understand is Open Loop input breaks the input conection and provide only the signal. Can any one helps to clarify my understanding.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/478068/image.png)
https://in.mathworks.com/help/slcontrol/ug/specify-model-portion-to-linearize.html
Thanks
S Arole
0 comentarios
Respuestas (1)
Paul
el 4 de En. de 2021
The linear analysis points (Input Perturbation, etc.) only apply for linearizing the model. They don't have any impact when running the simulation, which is what it sounds like is being done here.