How can I improve the response of this system with a hydraulic motor?

2 visualizaciones (últimos 30 días)
Pablo Sordo
Pablo Sordo el 2 de Feb. de 2021
Comentada: Pat Gipper el 3 de Feb. de 2021
I am trying to get the response of a system that converts the motion of a cylinder into rotational energy in a hydraulic motor. I think the design is fine, but the parameters don’t quite fit. The hydraulic motor is 250 cc.
I have a problem with the accumulator as can be seen in the figure Mid_Scope. I have tried varying the parameters many times, but I cannot smooth the signal.
The hydraulic motor also gives a very poor response: e-6 (Fig. w_Scope).
I would be grateful if someone could give me some advice to improve the results. Thank you very much in advance.
  2 comentarios
Pat Gipper
Pat Gipper el 3 de Feb. de 2021
I don't have Simscape Hydraulic, but there is nothing in your schematic that keeps the cylinder displacement flow from going right back into the the tank. Maybe you need to add two more check valves that direct the flow through the existing check valves and prevents the backflow.
Pat Gipper
Pat Gipper el 3 de Feb. de 2021
The check valves would be placed in the lines just above the SCOPE 1 and SCOPE 2 measurement points, with the check valves A port pointing down towards the tank.

Iniciar sesión para comentar.

Respuestas (0)

Categorías

Más información sobre Upgrading Hydraulic Models to Use Isothermal Liquid Blocks en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by