Hellow, im working with two motors for a project and they are connected via the Control instrument toolbox. Now i have used it in my gui, so the motor connect before the figure is shown. So in the function density_CreateFcn. But know, there must be a fault message when the gui starts and the motors arent connected properly. Anyone who has experience with this? Thx in advance
Respuesta aceptada
Más respuestas (3)
Sean de Wolski
el 13 de Mayo de 2011
0 votos
If the motor isn't connected it will error when it tries to connect to it because it won't be able to.
Post the full error message text for a more pinpointed response.
Walter Roberson
el 13 de Mayo de 2011
0 votos
I suspect that the answer you are looking for is that you should use a "try/catch" block around the fopen() for each of the motors. Though depending how you are finding the device information for the motors, you might be able to partly detect the condition earlier (e.g., if you only detect one COM port then you know that you don't have two motors connected.)
Fiboehh
el 13 de Mayo de 2011
1 comentario
Walter Roberson
el 13 de Mayo de 2011
The specific error for serial() failing to create the internal java object is MATLAB:serial:serial:cannotCreate
The specific error for serial fopen failing to open the internal java object is MATLAB:serial:fopen:opfailed
You can create an error dialog with
ed = errordlg({'Serial connection not established.', 'Please check connections and try again'});
uiwait(ed);