Process raw data using lowpass filter

24 visualizaciones (últimos 30 días)
nam bui
nam bui el 10 de Feb. de 2021
Comentada: Rahim Nami el 13 de Oct. de 2022
Hi,
I have a excel file with raw data containg 1200 rows and 2 columns named A and B. I'm try to apply a lowpass filter on the signal but looks like its not working, hopefully someone on here may have time to guide me to the right direction.
here is what I did so far:
imported data as a table -> created a script -> inside of the script -> load rawdata.csv
% sampling frequency [Hz]
Fs = 1000;
% sampling period [s]
Ts = 1/Fs;
% time vector [s]
t = 0:Ts:3;
% Signal A
sig_A = rawdata(:,1);
% Signal A
sig_B = rawdata(:,2);
order = 4;
fcut = 8000;
[sig_A,sig_B] = butter(order,fcut/(fs/2),'low');
x = filter(sig_A,sig_B);

Respuesta aceptada

Alberto Mora
Alberto Mora el 10 de Feb. de 2021
Editada: Alberto Mora el 10 de Feb. de 2021
You are confusing the filter coefficient with the raw signal.
Try this:
[b,a] = butter(order,fcut/(fs/2),'low');
sig_a_filt = filter(b, a, sig_A );
  5 comentarios
nam bui
nam bui el 10 de Feb. de 2021
this is help, thank you and I'll accep this as anwser for sure
Rahim Nami
Rahim Nami el 13 de Oct. de 2022
Hi everyone
Please, mathematical formula or mathematical model of the codes used. you insert
thank you
r_nami@gmx.com

Iniciar sesión para comentar.