Simscape Error ; The following Inductors are connected together
12 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Sreeraj A
el 24 de Mzo. de 2021
Comentada: Sreeraj A
el 26 de Mzo. de 2021
Hello,
I have a Boost PFC which I am trying to convert to interleaved architecture when tried running the simulation getting the error
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/561413/image.png)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/561418/image.jpeg)
Thanks in Advance.
1 comentario
hamza hamid
el 24 de Mzo. de 2021
Please me your Simulation model I will check the problem. This my email:hamidamza@yahoo.fr I have Matlab 2016b
Respuesta aceptada
Joel Van Sickel
el 24 de Mzo. de 2021
You can place a large resistor between the two inductors and connect it to ground. Start with 1e6 ohms.
Regards,
Joel
3 comentarios
Joel Van Sickel
el 25 de Mzo. de 2021
yes, that should be fine, but to see how much it is affecting your simulation, you can measure the current going through the resistor. If it is above 1-2% of your system current, you may want to make it larger. (the smaller the resistor, the more innacurate your model will be, but the faster it can simulate. The larger the resistor, the more accurate, but the slower the model might run).
Más respuestas (0)
Comunidades de usuarios
Más respuestas en Power Electronics Control
Ver también
Categorías
Más información sobre Simscape Electrical en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!