Hello:
I want ot know how to stop a simulink simulation automatically when one of the variables reaches a negative value. I will run it through a .m file
Thank you in advance
Respuesta aceptada
Más respuestas (2)
Fangjun Jiang
el 20 de Jun. de 2011
0 votos
Add an "Assertion" block into your Simulink model. The block is in the library Simulink>Model Verification. It has the option to stop simulation when assertation fails. You need to construct a simple logic to compare your signal to zero.
Javier Guiterrez
el 20 de Jun. de 2011
0 votos