Dynamically changing sample time for discrete time integrator

5 visualizaciones (últimos 30 días)
Hello, I am programming a dynamic chemical process which has a changing contact time (which changes the dt in the dC/dt equation). I have used a discrete time integrator with a sample time set to the contact time and this works just as I want it to however as I want the flow rate through the process to be variable and this will change the sample time I need to set. *I want to be able to set the sample time to value calculated else where in the model that changes. Does anyone have any advice for things I could try or know that this is impossible so I can stop trying?
Any extra details needed I will provide happily.
  1 comentario
Roger
Roger el 20 de Jun. de 2011
I have found a work around which is if the contact time is A then simply use a continous integrator with feed from equation that has dC/dt = A * x (where x is the original function). This gives me the desired answer I was looking for but I am a little wary of using this technique as I just made it up and am not sure of limitations / consequences. Any pearls of wisdom?

Iniciar sesión para comentar.

Respuesta aceptada

Guy Rouleau
Guy Rouleau el 21 de Jun. de 2011
Set the sample time of the discrete time integrator to be inherited and place it inside a triggered subsystem. You will need to make a logic to trigger the triggered subsystem at the right time.
  1 comentario
Roger
Roger el 22 de Jun. de 2011
Thank you Guy. The help of the community is massively appreciated.