Ahora está siguiendo esta publicación
- Verá actualizaciones en las notificaciones de contenido en seguimiento.
- Podrá recibir correos electrónicos, en función de las preferencias de comunicación que haya establecido.
This function gives a numerical result of the current generated by a specific PV array composed of M series-connected modules with bypass diodes, when a given voltage is applied to its terminals
Input variables
: Array voltage measured at the terminals [V].
: Photogenerated-current vector [A].
: Modules-Absolute-Temperature vector [°C].
: Number of cells connected in series (it is assumed that all modules are identical).
: Initial conditions for the numerical process , where is the PV_array current, and is the output voltage of the module. They are important in the numerical solution, and are taken from the every previous solution, in order to reduce convergence time and avoid some errors due to the complex equation-system structure. The following expression could be used in the first iteration , where is the short circuit array current;
Input parameters
(they are considered equal for each module)
: CELL Shunt Resistance [Ohms]
: CELL Series Resistance [Ohms]
: Diode saturation current [A]
: Diode ideality factor
: Bypass-diode saturation voltage [V]
The output is
: PV-array generated current [A]
Citar como
Edwin David Erazo Caicedo (2026). PV Array Model for PSCs (https://es.mathworks.com/matlabcentral/fileexchange/118710-pv-array-model-for-pscs), MATLAB Central File Exchange. Recuperado .
Información general
- Versión 1.0.1 (325 KB)
Compatibilidad con la versión de MATLAB
- Compatible con cualquier versión
Compatibilidad con las plataformas
- Windows
- macOS
- Linux
