Respondida
Simscape how to set up a multi-process evaporator or condenser
The architecture looks right: refrigerant in series and air flow in parallel, like the actual heat exchanger. A few things to p...

más de 2 años hace | 0

| aceptada

Respondida
How to model tanks with inlets above liquid level - partially filled pipes missunderstood?
You can find here two examples on how to use a tank block and a partially filled pipe together in an isothermal liquid model. T...

más de 2 años hace | 0

| aceptada

Respondida
Binary Mixtures using coolprop in Matlab
Looks like you can use the MATLAB wrapper for Coolprop to define a mixture and query the properties, like below: py.CoolProp.Co...

más de 2 años hace | 1

Respondida
How to plot pump and system curve based on the hydraulic model in Simscape / Simulink?
To summarize the discussion from the comments section: The pump curves can be generated from the pump blocks in Simscape Fluids...

más de 2 años hace | 0

Respondida
Connection between corrected mass flow and pressure ratio in the Turbine (G) Block
Summary from the discussion in the Comments section. While the formulation isn't given in the Documentation page of the Turbine...

más de 2 años hace | 0

Respondida
Definition of Reynolds number for MA side in Heat Exchanger (2P-MA) model
I checked the source code: for generic geometry, the hydraulic diameter is calculated as 4 * generic_fluid_volume / generic_he...

casi 3 años hace | 0

Respondida
Heat Pump Air Conditioner
Hello, I would suggest that you take a close look at this Documentation page "Model a Refrigeration Cycle" https://www.mathwor...

casi 3 años hace | 0

| aceptada

Respondida
Two-phase exchanger with evaporator that loses pressure at the outlet.
Check out this documentation page and carefully follow the workflow. https://www.mathworks.com/help/hydro/ug/modeling-a-refrige...

casi 3 años hace | 1

Respondida
Implementation of two-phase liquid out of REFPROP into simscape
In the same Documentation page, there is an example of using the same command to assign the properties to a Two-Phase Fluid Prop...

casi 3 años hace | 0

| aceptada

Respondida
How can I solve the error generated by a T-Junction when there is a Parallel Channels block in my simscape fluid model?
Hi Miguel, In the model you shared, the T-junction has the default initial flow target of 0 at all ports and "high" priority. ...

casi 3 años hace | 2

Respondida
Data center Simscape modelling
There is a shipping example on data center cooling, in R2023a. https://www.mathworks.com/help/hydro/ug/data-center-cooling.html...

casi 3 años hace | 2

Respondida
Fin Surface Area Condenser-Evaporator (2P-MA) Simscape Fluids
In the parameter dialog, the fin area for the MA side are for those thin foil/sheet you see on the outside of the tubes. The wa...

casi 3 años hace | 1

| aceptada

Respondida
Cooling system whit Ammonia not run
Hi Francesco, We believe the error has to do with the fact that NH3 has a non-monotonic supercritical line. It needs to be fix...

casi 3 años hace | 0

Respondida
Error using System-Level Refrigeration Cycle (2P)
Hi Carlo, We believe the error has to do with the fact that NH3 has a non-monotonic supercritical line. It needs to be fixed i...

casi 3 años hace | 0

Respondida
Simscape two-phase fluid in closed accumulator looses pressure
Hi Patrick, I believe what you are seeing is the result of the "upwind energy scheme" implemented at all ports of thermo-fluids...

casi 3 años hace | 1

| aceptada

Respondida
how mixing pressure Pm is calculated in gas ejector model of Matlab
This pm term is EVERYWHERE in the governing equations of the ejector. It's solved for implicitly to keep the system of equation...

casi 3 años hace | 1

Respondida
How to model actuator ports in Simscape fluids?
I'd encourage you to think more about the "effect" of a port in the actual system, instead of just having the actually values of...

casi 3 años hace | 0

Respondida
issues on Heat exchanger in simscape TL-MA
Setting reasonable parameters to discribe the nominal conditions for the heat exchanger seem to resolve the issue. Pay particul...

casi 3 años hace | 0

| aceptada

Respondida
In a Simscape Fluids/Hydraulic/IL centrifugal pump model, why is the flow higher after narrow pipe than directly after the pump?
In the Isothermal Liquid domain, the density of the fluid is a function of the pressure. See this documentation page: https://w...

casi 3 años hace | 3

| aceptada

Respondida
How can I mode the refrigeration cycle considering frosting in the evaporator in simscape
Hi Shuping, You are correct about the condensed water being removed right away (like magic) from the MA domain. Therefore, no ...

casi 3 años hace | 0

Respondida
Modelling a layer of water crossed by a water circulation.
Hi Lucas, Check out the attached modified .ssc file and a simple test harness. I keep most of the equations from constant volu...

casi 3 años hace | 0

| aceptada

Respondida
problem with ssc_build to generate custom simscape library
The input to the ssc_build command should be the directory name, instead of the .ssc file name. The directory can contain multi...

alrededor de 3 años hace | 0

| aceptada

Respondida
Two-Phase Cascade Heat Exchanger
Suggestion: check the parameters you've set for the heat exchanger, source, and reservoir blocks. Pay special attention to the ...

alrededor de 3 años hace | 0

| aceptada

Respondida
Modelling a layer of water crossed by a water circulation.
For the thermal liquid and almost all other fluids domains, you'll see a "port_convection" connection in the component block. C...

alrededor de 3 años hace | 0

Respondida
variation of liquid and gas over time and the pressure variation inside a tank
The two absoluate reference block I believe will enforce the temperature and pressure to be 0K and 0Pa, respectively. Use Cap i...

alrededor de 3 años hace | 0

| aceptada

Respondida
Increase power compressor 2 phases simscape
Scale up the mass flow lookup table inside the compressor map block. You will then get more flow for the same RPM and pressure ...

alrededor de 3 años hace | 0

Respondida
Can T-Junction (IL) be used to merge 2 pipe flows?
Yes, sure, although it's not necessary if you just want to merge two flows. You may just connect both B ports to the next compo...

alrededor de 3 años hace | 0

| aceptada

Respondida
Calculating Work done by a Closed Cylinder in Simulink and Simscape
You mentioned that you are using Simscape for the simulation of the cylinder. If that is indeed the case, I believe it would be...

alrededor de 3 años hace | 0

| aceptada

Respondida
What causes the pressure to be different in the shown figure when I use flow divider which must be dividing the flow equally?
The pressure sensor is an across variable sensor and no flow will go through the block. So your motor isn't getting any fluid t...

alrededor de 3 años hace | 0

| aceptada

Respondida
Which blocks could I use to model a hydraulic turbine in Simscape?
Some ideas: This hydraulic motor may be useful, though I suspect the shape of its performance curve may not be like that of a t...

alrededor de 3 años hace | 0

Cargar más