the model created seems not to behave phisically correct: heat exchanger reduces both temperature of TL and moisture air.
it should heat up air, cooling down fluid instead.
7 comentarios
Respuesta aceptada
Yifeng Tang
el 26 de Mayo de 2023
Setting reasonable parameters to discribe the nominal conditions for the heat exchanger seem to resolve the issue. Pay particular attention to units and type of information needed (mass flow vs. volumetric flow). The port size matters as well because the local velocity calculated based on port size and mass flow is also part of the energy flow calculation.