Hi... I create a model but appear the next error:
"The following two blocks cannot be connected in series because they are modeled as current sources:
Block 1: Ideal Switch1 Block 2: Subsystem/Controlled Current Source
Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device."
The Ideal Switch1 and the Subsystem/Controlled Current Source was SimPowerSystems but what resistor i use to correct the error?
1 comentario
Kaustubha Govind
el 27 de Jun. de 2011
I don't have any experience with SimPowerSystems but you could possibly set a large value for the "Snubber resistance Rs" parameter in the Ideal Switch dialog, as the error message suggests.
Respuesta aceptada
Más respuestas (3)
Arnaud Miege
el 28 de Jun. de 2011
3 votos
Just use a Series RLC Branch in parallel with your ideal switch, but keep everything on the SimPowerSystems side (i.e. the resistor should between ports 1 & 2 of the ideal switch).
HTH,
Arnaud
1 comentario
Nuno
el 30 de Jun. de 2011
Nuno
el 26 de Jun. de 2011
0 votos
Nuno
el 28 de Jun. de 2011
0 votos