How to achieve 100% Mc/Dc coverage for model having Temporal logic 'tick'?
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
Hi,
Am testing Model for MC/DC coverage, That model is having temporal logic 'tick', Temporal event tick is never false, so I cant able achieve 100% MC/DC. Pls guide me in this?
0 comentarios
Respuestas (1)
Arunkumar M
el 11 de Nov. de 2018
for example you have use temporal logic in condition say after(10,tick), then one test case should test this condition and pass 10 ticks and other test case should terminate before completion of 10 ticks. In this case, you would have achieved once TRUE and FALSE for this temporal logic condition, which should give you 100% coverage