Simulink Fixed Step Size Discrete Compiler - two different step sizes in .cpp file?
2 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hi Everyone,
When I generate my code from the Simulink Coder (2011a), in my .cpp file I get
290 /* Model step function for TID0 */
291 void TEST_step0(void) /* Sample time: [0.04s, 0.0s] */
292 {
293 /* (no output/update code required) */
294 }
295
296 /* Model step function for TID1 */
297 void TEST_step1(void) /* Sample time: [1.0s, 0.0s] */
I want the step size to always be 0.04s...I set the solver to this value, and I'm not sure why it is giving me a second sample size.
thanks, B.
0 comentarios
Respuesta aceptada
Kaustubha Govind
el 13 de Jul. de 2011
You probably have blocks in your model that have a sample time of 1s (blocks in a model with a fixed-step solver can have a sample-time that is a multiple of the solver step-size). Look at the sample-time colors in your model to find the blocks and assign them to have a sample-time of 0.04s.
0 comentarios
Más respuestas (1)
Daniel
el 22 de Feb. de 2012
I had this problem too, but I used the advanced search to look up the blocks with property "Sample time" with value "1".
0 comentarios
Ver también
Categorías
Más información sobre Simulink Coder en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!