Borrar filtros
Borrar filtros

Sample time setting for high frequency systems

6 visualizaciones (últimos 30 días)
Stephen
Stephen el 15 de Ag. de 2011
What sample time should I use when simulating a system operating at 100 kHz?
It seems to me that the typical 0.2 seconds would be to small.
Are there quidelines for determining the appropriate sample time?

Respuestas (2)

Fangjun Jiang
Fangjun Jiang el 15 de Ag. de 2011
A 100kHz signal means its period is 10us. If the signal is a sine wave, you would need about 20 data points to represent a complete cycle of a sine wave with good quality. That means 0.5us is your maximum step size or sample time. 0.2 seconds is way bigger.

Stephen
Stephen el 15 de Ag. de 2011
Thanks,
Should the sample time for all elements in the system be set to the 0.5 usec (the number in the above post) or just those that are actually operating at that frequency (100 kHz). Can other elements be set to a slower data rate?
  1 comentario
Fangjun Jiang
Fangjun Jiang el 15 de Ag. de 2011
Sure. The proper sample time should be determined by the need of the application. To measure the noise level and temperature of a living room, for example, could have quite different sample time.

Iniciar sesión para comentar.

Categorías

Más información sobre Simulink en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by