Hi guys.
I have a model. I want to run two different clock separately and with different starting points. For example: My model starts at t=0. one of the clocks should start immediately and produce a signal. When the signal reaches a defined value, I want my second clock to start.
I used enabled and triggered subsystems but it didn't work. I also prefer not to use ramp with initial value.
It would be more pleasant if I can start the second clock by other means.
Thank you for your time.
0 comentarios
Respuesta aceptada
C.J. Harris
el 7 de Jul. de 2014
You can create a 'clock' using a discrete integrator. For example if you can set the time-step of the integrator equal to model sample time, and feed it a constant input of 1 it will act like a clock.
The initial condition of the integrator can be used to control the starting value of the 'clock', and the reset condition can be used to control when the timer starts (or resets). Therefore you can feed the output from your first 'clock' into a compare block in order to generate the necessary reset signal (to start your second 'clock').