Control Simulibk step size through an internal coondition
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
I have implemented some blocks (S-Function level-2 using Matlab code, matlab function block...etc) in simulink, and I have an internal stability condition which will determine the step size after each simulation step. I know that I can set the solver to a variable step solver, but how can I make simulink check for the different obtained step sizes, and then, impose the smallest to all blocks? For the time being , I am using the following trick:
set_param(bdroot,'MaxStep',num2str(dT));
set_param(bdroot,'MinStep',num2str(dT*0.9999));
because the minimum and maximum steps cannot be the same. However, this is not working good enough.
0 comentarios
Respuestas (1)
Christopher Berry
el 11 de Ag. de 2014
Anfanger,
In order for the parameters MinStep and MaxStep to be enabled, the solver Type must be VariableStep. If you are using a fixed step solver, then these settings will just be ignored. So make sure you are using a variable-step solver, like ode45.
Also, I have no problems setting the MinStep and MaxStep to the same values, what error are you getting when you do:
set_param(bdroot,'MaxStep',num2str(dT));
set_param(bdroot,'MinStep',num2str(dT));
Other than that, this method seems like it should work, so what about it specifically is not good enough?