Scope in Simulink does not display waveform correctly

17 visualizaciones (últimos 30 días)
Michail
Michail el 2 de Dic. de 2014
Comentada: Amira benAmeur el 10 de Ag. de 2017
Hello!
In Simulink I implement a very simple circuit with an AC voltage source (110kV,50Hz) in series with a Resistance R=1 Ohm and PowerGUI set to Discrete (Ts=5e-5s). I use also a "voltage measurement" block and a Scope to display the voltage waveform of the source. When I set the "Stop simulation time" to 0.2s the waveform is displayed from 0 to 0.2s as it was expected but when I set it to 0.4s it starts from around 0.15s (???). The same behavior occurs when I just use "Sine wave function" block with a Scope. There is something wrong with the scope because when I plot through the workspace everything is ok.
I would be grateful if somebody has a solution on this issue and could share it!
Regards, Michail

Respuesta aceptada

Azzi Abdelmalek
Azzi Abdelmalek el 2 de Dic. de 2014
Editada: Azzi Abdelmalek el 2 de Dic. de 2014
I suppose your sample time is very small, in the scope parameters-history uncheck limit data point to last
  2 comentarios
Michail
Michail el 2 de Dic. de 2014
Perfectly right! Thank you very much for your help!
Amira benAmeur
Amira benAmeur el 10 de Ag. de 2017
Thank you for your help!

Iniciar sesión para comentar.

Más respuestas (1)

Alireza Babaloo
Alireza Babaloo el 3 de Feb. de 2016
I had the same problem thanks.