Connect Multiple Constant Volume Chambers.
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Tobias Lorscheider
el 30 de Mzo. de 2022
Comentada: Tobias Lorscheider
el 4 de Jul. de 2022
Hello everyone.
Is it possible to connect multiple volume chambers with each other? The idea behind is that I want to have a vehcile cabin as implemented in the following Matlab example of a Electric Vehicle Thermal Model, but divided into different zones, e.g. front right, front left, etc. Just connecting the moist conserving ports does not seem to work. Is this even the correct approach or is what I want to implement even possible?
https://de.mathworks.com/help/physmod/hydro/ug/sscfluids_ev_thermal_management.html?s_tid=srchtitle_vehicle%20thermal%20model_1
0 comentarios
Respuesta aceptada
Yifeng Tang
el 29 de Jun. de 2022
Conneting ports of multiple constant volume chambers is DIFFERENT than connecting say multiple pipes to a same point. Connecting the volumes can create constraints for the states inside these volumes, so you can imagine that they become one same volume. Add some flow resistance between the ports, and you should be OK. You can make the resistance very small. Multi-zone cooling/heating in a passenger cabin or a multi-room building can be done this way.
Más respuestas (0)
Ver también
Categorías
Más información sobre Foundation and Custom Domains en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!