Filter data through a bandpass FIR
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
I have multiple sets of data, all with the same timesteps, sample size of 4000, and sampling frequency (Fs) of 50MHz but different frequency based values. Each dataset has a different central frequency (Fc) from 2.4 - 0.6MHz, and has a bandpass filter (BP) of BP = [0.9*Fc 1.1*Fc]. I've tried a digital filter of:
df = bandpass(data(:,2),BP,Fs,'ImpulseResponse','fir');
This filter works for the first few datasets of higher frequencies, but stops when halfway through an error message says "Data length must be larger than 4362 samples". How can this be fixed without compromising the results, or is there a better filter to use?
0 comentarios
Respuestas (1)
Star Strider
el 26 de Jul. de 2022
That’s a problem with FIR filters, simply because in most instances they tend to be very long vectors.
Use an IIR filter instead:
df = bandpass(data(:,2),BP,Fs,'ImpulseResponse','iir');
This will design and implement a very efficient elliptic filter.
.
0 comentarios
Ver también
Categorías
Más información sobre Filter Design en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!