How to change the transfer function variable in simulink during simulation time
Mostrar comentarios más antiguos
Hi,
I have a Simulink model, where I need to change the transfer function coefficient during simulation run time. For example the TF is (1/1+sRC). Here R and C values need to change during run time. How to do that? Problem here is that the R value is calculated with the load current, that is (output voltage)/(load current). So I know the load current variation by calculating the R values. If anyone knows how to change the TF coefficient during runtime please help me. Thanks in advance.
Respuestas (1)
Paul
el 7 de Sept. de 2022
0 votos
Hi Swasthik,
If I understand correctly, the R and C values are changing dynamically. Just use blocks (integrators, subtraction, product, etc.) to implement the first order differential equation explicitly. The Transfer Function block is intended to be used with fixed parameters.
4 comentarios
Swasthik Baje Shankarakrishna Bhat
el 8 de Sept. de 2022
Sam Chak
el 8 de Sept. de 2022
can be expressed in the 1st-order Differential equation form:
If R is a function of the state
, then using the Integrator block and some fundamental blocks, you can construct the signal flow according to this Integral equation:
Swasthik Baje Shankarakrishna Bhat
el 19 de Sept. de 2022
Sam Chak
el 19 de Sept. de 2022
Categorías
Más información sobre General Applications en Centro de ayuda y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!