How to change the transfer function variable in simulink during simulation time

12 visualizaciones (últimos 30 días)
Hi,
I have a Simulink model, where I need to change the transfer function coefficient during simulation run time. For example the TF is (1/1+sRC). Here R and C values need to change during run time. How to do that? Problem here is that the R value is calculated with the load current, that is (output voltage)/(load current). So I know the load current variation by calculating the R values. If anyone knows how to change the TF coefficient during runtime please help me. Thanks in advance.

Respuestas (1)

Paul
Paul el 7 de Sept. de 2022
Hi Swasthik,
If I understand correctly, the R and C values are changing dynamically. Just use blocks (integrators, subtraction, product, etc.) to implement the first order differential equation explicitly. The Transfer Function block is intended to be used with fixed parameters.
  4 comentarios
Swasthik Baje Shankarakrishna Bhat
Swasthik Baje Shankarakrishna Bhat el 19 de Sept. de 2022
Thank you so much paul and sam. It worked. Sorry for the late reply. Regards, Swasthik