Simscape Fuel Cell - unexpected behavior

2 visualizaciones (últimos 30 días)
Francesco Cerrito
Francesco Cerrito el 9 de Sept. de 2022
Respondida: Sabin el 20 de Dic. de 2022
Good morning, I am trying to use the Fuel cell block in the Simscape environment with model fidelity sets on Simplified - nominal conditions.
I implemented a simple code to check the right behavior of the system. In particular, I compared the analytical polarization curve and the polarization curve obtained by Simscape measuring the fuel cell voltage and the current. I used a variable resistor to set the working conditions.
I would like to understand why there is this difference.
close all
clear
clc
%% Parameters
Eoc = 65; %[V]
A = 0.23; %[V]
N_unit = 10;
i0 = 80; %[A]
N = 65;
Ri = 0.05; %[Ohm]
ifc = linspace(0,300,1e3);
E = Eoc - N*A*log(ifc/i0);
vfc = N_unit*E-Ri*ifc;
%% Simulation
sim("FCsimscapeModel.slx")
%% Plot
figure, plot(ifc,vfc,'LineWidth',2), grid on, grid minor, hold on
plot(ans.current.Data, ans.voltage.Data, '--','LineWidth',2)
axis([0 300 0 1600])
legend ('Analytical polarization curve', 'Simscape polarization curve')

Respuesta aceptada

Sabin
Sabin el 20 de Dic. de 2022
We are aware of this behaviour which is cause by a small internal resistance used for protection. This will result in a small voltage drop. The workaround would be to measure the internal voltage using a Probe block rather than measuring with a voltage sensor. This will be corrected in future releases.

Más respuestas (0)

Productos


Versión

R2022a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by