Position error of motor shaft
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
saleh shlimet
el 13 de Dic. de 2022
Comentada: Mathieu NOE
el 20 de Dic. de 2022
I want to obtain the position error of motor shaft so I subtracted the estimated position from the measured position. modulus function is used so the estimated and the measured positions vary between 0 to 2pi (electrical radians) as shown in the figures attached. the problem is that the error becomes 2pi at instant times. What can I do to not show this big error (2pi) in the figure?
0 comentarios
Respuesta aceptada
Mathieu NOE
el 13 de Dic. de 2022
Movida: Joel Van Sickel
el 15 de Dic. de 2022
hello
you can make 2 pi complements on the error signal , following that logic
if error < -pi then error = error + 2pi
if error > pi then error = error - 2pi
goal is to keep error witin -pi / + pi bounds
13 comentarios
Más respuestas (0)