Can someone explain me the DC Motor Figure result?

2 visualizaciones (últimos 30 días)
Alex Kolegkas
Alex Kolegkas el 5 de En. de 2023
Respondida: Sabin el 5 de En. de 2023
Hello everyone,
As i see on the figures (characteristics) for the 5 different type of motors, We have a linear characteristic on the DC motor after 5629 RPM (Torque- speed characteristic) and after 5626 RPM (Power-speed characteristic). I can't understand the model - why we don't have a linear characteristic starting from 0 RPM or 0 Watt.
Thank you in advance
Yours,
Alex kolegkas

Respuesta aceptada

Sabin
Sabin el 5 de En. de 2023
The problem here is that Simscape data logging is limited to 10000 points but in the DC-Motor case the solver needs more points to simulate 60 seconds. Therefore, the plot function is displaying only the last part of the characteristics. A quick workaround would be to uncheck the ‘Limit data points’ box in the Configuration Parameters/Simscape: