Is the power system frequency measured in Phasor mode or Descre or Congtinuse mode?
1 view (last 30 days)
Show older comments
Is the power system frequency measured in Phasor mode or Descre or Congtinuse mode?
1 Comment
Sabin
on 27 Jan 2023
Would be helpful to specify what model are you refering to? Also please give a bit more insights into what are you tryibg to do.
Accepted Answer
Joel Van Sickel
on 16 Feb 2023
In phasor mode, the power system frequency is specified, not measured. The whole power system will simulate at that frequency and not include effects that would case the frequency to change. In continuous and Discrete mode, you can measure the frequency and the frequency can change over time.