Error Regarding Simulink's Input Workspace Sample Time Parameter

1 visualización (últimos 30 días)
Ava Lindquist-Sher
Ava Lindquist-Sher el 6 de Feb. de 2023
Respondida: Yuvraj Singh el 24 de Feb. de 2023
I wanted to confirm the signal viewed in Simulink was the same as when viewed in MATLAB, however that was not the case. That is when I noticed the error messages pictured. However, when checking the choosen Sample Time parameter values I didn't see any reason for error message since the its values were non-negative and a real double vector. Any suggestions on how to fix?

Respuestas (1)

Yuvraj Singh
Yuvraj Singh el 24 de Feb. de 2023
Hi Ava,
Sample Time expects its input to be a real doube scaler or real doube vector of length 2(period,offset). In your case, vOut_T2 is filled as Sample Time, whose dimensions are <double1375001x1>.

Productos


Versión

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by