- Please check if your model has any unconnected port warnings, as that may be the root cause of the error.
- The error itself is manifested during the code report web view generation. Upon turning off report web view generation (in the model's configuration parameters uncheck PLC Code Generation > Report > Generate model web view), the model then generates code without any errors. This is a workaround to avoid the error, but it is recommended to look into removing those unconnected port warnings as well.
PLC Code - Generate PLC Code: Too many input arguments error
2 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I am using a PLC Controller Suite block from studio5000_plclib, I have set it up with ladder logic and it works fine in simulation, however when I go to generate PLC code nothing happens and I get this error in the diagnostic viewer:
It doesn't seem to matter what IDE I set it up for, or if the PLC Controller Suite block has any logic in it. I've tried looking it up, but just get basic MatLAB related errors.
0 comentarios
Respuestas (1)
Gowthami
el 19 de Abr. de 2023
Hi Micah,
It is my understanding that you are getting a "Too many input arguments" error when trying to generate structured text using the PLC coder.
I would recommend you go through the following steps:
0 comentarios