I am working on this simulation and it gives me this error. What can I do?
An error occurred while running the simulation and the simulation was terminated
Caused by:
  • Derivative of state '1' in block 'hwmid/Aerodynamic_Data/total forces/Subsystem/Integrator' at time 0.0 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
Component:Simulink | Category:Block error

Respuestas (1)

Walter Roberson
Walter Roberson el 19 de Abr. de 2023
Derivatives not being finite at time zero are typically mistakes in initialization -- in particular, forgetting that input signals that are updated by a feedback model need to be initialized
But it is also not uncommon to have a model that effectively has a division by t (time) and forgetting that at time 0 that means a division by 0.