switch case
30 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
shahid Alam
el 28 de Oct. de 2011
Comentada: ahmed al-kady
el 9 de Nov. de 2015
i need help here...to run a system in simulink an error is showed : Port 2 of 'final/Subsystem4/Subsystem2/Switch Case' can only be connected to an action subsystem and may not be connected to more than one action subsystem....if possible plz help me here.....
0 comentarios
Respuesta aceptada
Fangjun Jiang
el 28 de Oct. de 2011
The message is clear. The output of the "Switch Case" block can only be connected to one (and only one) "Switch Case Action Subsystem" block, which can be found in library "Ports & Subsystems". Remember to connect the "Action Port", not the "Inport".
Open sl_subsys_sw1.mdl to see an example.
0 comentarios
Más respuestas (1)
shahid Alam
el 28 de Oct. de 2011
2 comentarios
Fangjun Jiang
el 28 de Oct. de 2011
The output of the "Switch Case" block is a trigger. It can only trigger one subsystem. If you need to trig more than one, you can probably put all the things that you want to trig inside the "Switch Case Action Subsytem".
You can add as many Inport blocks as you want.
ahmed al-kady
el 9 de Nov. de 2015
please i need to reset the switch case after triggering another case, as it hold the output even if the input signal is changed. thanks in advance.
Ver también
Categorías
Más información sobre Schedule Model Components en Help Center y File Exchange.
Productos
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!