outputs to workspace not visible

10 visualizaciones (últimos 30 días)
Amardeep
Amardeep el 31 de Oct. de 2011
Greetings all; I am running simulink from a Matlab script using the sim command and have inputs all as constants from the base workspace and am trying to output to the current workspace. However when I try to use the outputs I get the error that the output is an undefined function or variable (the inputs are being pulled in correctly).
I am calling the sim thusly:
myopts = simset ('ReturnWorkspaceOutputs','on','DstWorkspace','current'); sim('model',[],myopts);
My outputs are done as 'To Workspace' blocks. I have tried pre-defining the outputs but they dont then get written over with data after the model runs. I have left the time option empty as its a single run and thats all defined in the configuration parameters.
Regards
Amardeep

Respuesta aceptada

Fangjun Jiang
Fangjun Jiang el 31 de Oct. de 2011
Your 'script' must have been a M-function, instead of a M-script. Setting 'DstWorkspace' to be 'current' means sending the output to the current workspace. You need to set it as 'base'.

Más respuestas (0)

Categorías

Más información sobre Simulink en Help Center y File Exchange.

Productos

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!