unable to resolve cooling plate error

4 visualizaciones (últimos 30 días)
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT el 26 de Jul. de 2023
Respondida: Joel Van Sickel el 28 de Jul. de 2023
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
  3 comentarios
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT el 26 de Jul. de 2023
Thanks for responding sir. I have used battery builder app to build the battery module with 14X14 cylindrical cells. ambient coolant path and coolant thermal path are set to " cell based internal resistance". i have attached the model along with cooling plate parameters.i am not sure if the parameters of cooling plate matching with nodes of battery module? please help.
Hyunwoo
Hyunwoo el 27 de Jul. de 2023
I have the same problem, did you solve it?

Iniciar sesión para comentar.

Respuesta aceptada

Joel Van Sickel
Joel Van Sickel el 28 de Jul. de 2023
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.

Más respuestas (0)