Error in first-level analysis using SPM12, seeking assistance.

10 visualizaciones (últimos 30 días)
john
john el 8 de Ag. de 2023
Comentada: john el 8 de Ag. de 2023
The analysis has been successful for data from other groups, but this issue is occurring specifically with this group.
Index exceeds the number of array elements. Index cannot exceed 0.
In file "D:\Matlab\toolbox\spm12\config\spm_run_fmri_spec.m" (v7739), function "spm_run_fmri_spec" at line 136.
The following modules did not run:
Failed: fMRI model specification
The code that caused the error is
“if ~isempty(sess.multi{1})“

Respuestas (1)

Florian Bidaud
Florian Bidaud el 8 de Ag. de 2023
Editada: Florian Bidaud el 8 de Ag. de 2023
This means sess.multi is an empty cell array, therefore you can't call sess.multi{1} because it does not exist.
You should add something like the following, before checking if sess.multi{1} is empty.
if ~isempty(sess.multi)
  3 comentarios
Florian Bidaud
Florian Bidaud el 8 de Ag. de 2023
Editada: Florian Bidaud el 8 de Ag. de 2023
Without knowing how the data is, I'm afraid I can't explain why there is an empty element. But the error you got tells you that you have indeed an empty element in your data.
I wouldn't advise modifying the spm code, but maybe have a look on your data instead, to identify why you get these empty cells
john
john el 8 de Ag. de 2023
Okay, thank you, I'll check the data for errors