Minimum step size (2.0) is larger than discrete sampling period (0.5)
Component:Simulink | Category:Model error
I tried running a model in simulink and this is what it keeps showing. Are there any suggestions on how i can increasing the discrete sampling period.
0 comentarios
Respuestas (1)
Fangjun Jiang
el 18 de Ag. de 2023
Press Ctrl+E to bring up the configuration parameters, Solver, set the Minimum step size from 2.0 to at least 0.5, or better at 0.1.
2 comentarios
Fangjun Jiang
el 20 de Ag. de 2023
First you need to set the model correctly and run simulation. Then you can talk about fast or slow simulation speed.
If there is no other constraint, you could change the discrete sample time from 0.5 to something larger, for example 2.0. Then you could make the mininum step size to be the same as that discrete sample time. It will run and it probably will be faster.
You need to find the blocks that determines the 0.5 discrete sample time to change it.