- Line current that we measure must be converted to phase current
- An offset (-(120/N)*pi/180) is needed for electrical angle used in transformation of current from abc to dq. N is the number of polepairs.
Setting offset in torque control and Delta connection
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
adhavan d
el 30 de Ag. de 2023
Comentada: adhavan d
el 27 de Sept. de 2023
Hi,
my model is based on ipmsm torque control with delta connection.
So,I used 30 degree (-0.523599 - rad) offset wwith electrical theta for 500 rpm and 60 nm.it works.
but when I used 30 degree(-0.523599 radian) offset with electrical theta for 8500 rpm and 16 nm,The machine torque can not been met request torque.
How to set offset value for all speed and torque in delta connection.
0 comentarios
Respuesta aceptada
Sabin
el 21 de Sept. de 2023
When using delta connection there are 2 changes that are needed:
The Three-Phase PMSM Drive example in Simscape Electrical shows how to use the controller in case of wye and delta. I hope this helps.