PLC Coder does not support the usage of machine parented data. How can I solve it?
2 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Alice Passarella
el 1 de Sept. de 2023
Respondida: Shivang
el 4 de Sept. de 2023
I am currently working on Stateflow (Simulink) to generate a PLC Code compatible with Rockwell.
I am currently facing incompatibility issue: PLC Coder does not support the usage of machine parented data objects. How can I solve it without deleting such data?
Thanks
0 comentarios
Respuesta aceptada
Shivang
el 4 de Sept. de 2023
Hi Alice,
I understand you're running into an issue regarding the usage of machine-parented data objects in Stateflow.
Note that starting in R2023a, Stateflow charts no longer support machine-parented data. You will need to convert machine-parented data to chart-parented data store memory.
You can run Upgrade Advisor to fix this issue. Upgrade Advisor will automatically check the model for instances of machine-parented data. You will then be presented with an option to "Upgrade model", which will create chart-parented data in the charts that use machine-parented data.
Refer to the documentation for more details: https://www.mathworks.com/help/simulink/slref/simulink-checks_bq6d4aa-1.html#mw_94a64beb-dfcf-44c3-af52-82eaa725bc06
Hope this helps.
-Shivang
0 comentarios
Más respuestas (0)
Ver también
Categorías
Más información sobre Simulink PLC Coder en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!