I am facing problem when I am using frequency analyzer in Simulink.

1 visualización (últimos 30 días)
Yojan
Yojan el 11 de En. de 2024
Respondida: Siddharth Jawahar el 24 de En. de 2024
I am getting this error when I am plotting bode plot for my three level inverter model(using PID Controller).
In "frestimate(modelname,op,io,in)", it is required for each of the linearization input I/O points that the sample time of the Simulink signal where it is located is one of the following: 1. It is either continuous or fixed in minor time step. 2. Its sample rate is equal to the sample rate of the input signal "in". The linearization I/O io(1) does not satisfy this requirement. Consider either changing the sample time of Simulink signal where io(1) is located to continuous sample time or changing the sample time of input signal "in".
  3 comentarios
Yojan
Yojan el 11 de En. de 2024
Movida: madhan ravi el 11 de En. de 2024
I am getting same error by using this also.

Iniciar sesión para comentar.

Respuestas (1)

Siddharth Jawahar
Siddharth Jawahar el 24 de En. de 2024
Hi Yojan,
I recommend ensuring that the sample time of the input signal matches that of the signals marked as the linear analysis I/O points in the model.
Best,
Sid

Categorías

Más información sobre Offline Frequency Response Estimation en Help Center y File Exchange.

Productos

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by