Incorrect result from camera calibrator app
Mostrar comentarios más antiguos
I used the camera calibrator app to calibrate lens distortion and I specified correct checkerboard size of 8mm. The calibration goes fine and i'm able to undistort images and points. However, the plot from showextrinsics() shows camera at 8mm distance from object but in reality it is 140mm. Why is this wrong?
My setup has a camera looking downwards and pattern is placed at the same working distance in all 30+ images where the lens is focused.
Calibration settings: All default settings - Standard lens, 2 coeffs, no tangential distortion, no skew, etc.



4 comentarios
Qu Cao
el 18 de Mzo. de 2024
It looks to me that all the images are almost placed in the same plane. For accurate calibration results, we recommend taking images from different orientations and view angles.
cr
el 18 de Mzo. de 2024
Giridharan Kumaravelu
el 19 de Mzo. de 2024
Would you mind providing us with the calibration images to help troubleshoot this behavior?
Respuesta aceptada
Más respuestas (0)