hello, when i generate the code from simulink model, i find the head file include (zero_crossing_types.h),but i do not want include this, how to resolve it.
0 comentarios
Respuesta aceptada
Fangjun Jiang
el 28 de Mzo. de 2024
un-check the "Enable zero-crossing detection for fixed-step simulation" option in the Solver setting?
Also, search for "zero-crossing" in the configuration parameters to see if any other related settings might have affected the inclusion of this header file.