Hello everyone, I want to use Double-Acting Servo Valve Actuator (IL) for my project. I want to print the signal I receive from this actuator with any sensor and compare it with the reference value. However, I could not find such an example. If you could help with this situation, I would greatly appreciate it.
  1 comentario
Yifeng Tang
Yifeng Tang el 23 de Jul. de 2024
Could you please clarify on "the signal I receive from this actuator"? Did you mean the pressure and flowrate at each port or something else?

Iniciar sesión para comentar.

Respuestas (1)

Epsilon
Epsilon el 26 de Feb. de 2025
Editada: Epsilon el 26 de Feb. de 2025
Hi Yakup,
The 'Double-Acting Servo Valve Actuator (IL)' block is a Simscape block, which utilizes a physical signal. To compare this signal with a reference value using other Simulink blocks, it is necessary to convert the physical signal into a Simulink signal.
This conversion can be achieved with the 'PS-Simulink Converter' block. After conversion, the signal can be compared to a reference value using a 'Compare to Constant' block.
For more information on the blocks mentioned above, type<help 'block name'> in the command window.