Dear all,
I faced an issue with algebraic loop in simulink (see the model attached).
When I update the model it says "Algebraic loop error", even though there seem to be no algebraic loop at all.
The issue is resolved if I combine these two subsystems into a one.
Could you please explain where the algebraic loop is coming from?
Thank you!
0 comentarios
Respuesta aceptada
Walter Roberson
el 29 de Sept. de 2025 a las 16:49
The ready_out of toRAM_interface is an output. You send that to ready_in of the FIFO. Meanwhile, the FIFO has lines that are inputs to the toRAM_interface.
Everything that is connected has to be true at the same time unless separated by a zero order hold or memory block or rate transformation (including a 1/z block with a very short time constant. (I might be overlooking some other cases.) So your connected series means that the ready_out from the toRAM_interface has to be true at the same time as the outputs of the FIFO and the output lines of the FIFO. Even if we suppose that the read_out line is the trigger for the FIFO to send information, no time is being alotted for the *_out lines to settle or for the ready_out line to change state in response to the *_in being received. That is an algebraic loop.
Your system either needs a delay on the ready_out line, or else delays on the *_out lines that are input to the toRAM_interface
3 comentarios
Walter Roberson
el 1 de Oct. de 2025 a las 3:15
Suppose we are at the state where toRAM_interface has just set ready_out to be true, thereby triggering the FIFO to send samples. We will simplify the discussion by focusing on the beginning of the ready_out pulse, ignoring any time before that. We will also simplify by assuming that FIFO reacts to the ready_out pulse immediately, making data for the *_out lines immediately available.
Now at some point, the toRAM_interface needs to signal that it is busy (because it is reading the *_out signals and processing them.) When that happens, toRAM_interface will set ready_out to false.
Here is the thing: it takes time for ready_out to flip to false.
Consider the contrary: if it did not take any time for ready_out to become false, then it would become false simultaneously with it becoming true to signal that toRMA_interface is ready. But no signal can be simultaneously true and false, and Simulink cannot process the possibility of a signal being simultaneously true and false.
The Simulink interface between FIFO and toRAM_interface needs to be configured so Simulink knows that there is time between ready_out becoming true and ready_out becoming false. Even if the time is only 50 nanoseconds, there needs to be a delay line or a zero-order hold or a memory block or a transfer function (I might have overlooked options) on the line so that Simulink is not trying to figure out how to handle the situation of ready_out being simultaneously true and false.
Más respuestas (1)
Sam Chak
el 1 de Oct. de 2025 a las 8:31
Movida: Sam Chak
el 1 de Oct. de 2025 a las 8:33
Hi @Sergei
Unmasking the 'FIFO' and 'toRAM_interface' blocks allows you to observe the signal dependence and identify the algebraic loop issue. The StreamFIFO block requires a feedback signal (ready_signal) that appears to originate from the Bus Object registered in both the toRAMctrl and fromRAMctrl ports. By default, Simulink's data type propagation for input and output ports uses the "Inherit: Auto" setting.
If you merely want to test the functions of the three SoC blocks, you can temporarily replace the toRAMctrl and fromRAMctrl ports with the Terminator and Ground blocks, respectively.
[data signal, valid_signal, ~] = StreamFIFO(data_in, valid_in, ready_signal)
toRAMctrl = SoCBusCreator(0, 0, valid_signal)
[ready_signal, ~, ~] = SoCBusSelector(fromRAMctrl)
Unmasked SoC subsystem

Workaround

3 comentarios
Sam Chak
el 1 de Oct. de 2025 a las 13:25
Hi @Sergei
In the actual scenario, this SoC subsystem is probably connected to a much larger system via the RAM Controller for signal processing tasks, through multiple Simulink blocks that may be static (where signals are transmitted instantaneously) or dynamic (where a delay occurs as data travels from a sending point to a receiving point on a network).
If the blocks on the RAM side of the system are all static, a circular dependency will arise. Conversely, if the RAM side of the system includes some dynamic blocks with properly specified initial conditions, a circular loop will still exist, but it will not depend algebraically.
Note: If you cannot view the "Workaround" block diagram, click the attached image in this post.