Voltage shrinkage at higher speed around 0.3 of rated of speed and i'm computing line to line voltage from PWM which i captured using logic analyzer.
8 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hey I'm controlling pmsm motor using FOC , i observed at that higher speed the duty cycle as well as line to line voltage is shriniking what can be the possible reason behind that ?
the pink region is sinousodul waveforms of line to line voltage as you can see that at higher speed it shrinked.

2 comentarios
Rosa
el 29 de Oct. de 2025
The shrinking line-to-line voltage (pink area) at higher speeds is expected behavior in PMSM FOC systems.
It typically means the motor has entered the field-weakening region, where the controller intentionally reduces the effective flux to stay within the DC-bus voltage limit and maintain safe inverter operation.