Good day everyone,
I recently creating a relatively large battery pack using Simscape Battery Builder. I set up a simple charging and discharging cycle to test it but the SoC I'm getting from the battery pack is discharging slower than expected. I added an estimator block which is giving me SOC values that seem more reasonable. Is there something I missed in creating the battery causing the difference?
This is also affecting the battery degradation/aging since it's based of th number of cycles. I've attached the model and code I used to create the battery pack. Thank you.

Respuesta aceptada

Leepakshi
Leepakshi el 19 de Nov. de 2025
Hi,
The slower SoC discharge is often due to how the battery pack calculates SoC versus the estimator. First, check the terminal voltage vs. open-circuit voltage (OCV)—terminal voltage includes the drop from internal resistance under load. If you need accurate charging behavior, use a CC-CV block for constant voltage charging. Also, review initial conditions: setting both initial SoC and initial voltage with high priority can cause conflicts, define only one.