Control algorithm stops working after 5 min 30 sec on F28335.

2 visualizaciones (últimos 30 días)
ashish ahir
ashish ahir el 31 de Ag. de 2015
Movida: Sabin el 20 de Dic. de 2022
I want to generate A sin(Wt) with A and W as external signals. As shown in figure i have done that. Sample time for blocks is 50e-6. I am using this block in inverter control algorithm. After downloading code on F28335 controller, it stops controlling after 5 min 30 sec. p.s. if i use inbuilt sine source block, it works fine. But, i want A and W configurable from external signals.

Respuestas (1)

Jeevan Thomas
Jeevan Thomas el 11 de Sept. de 2015
Movida: Sabin el 20 de Dic. de 2022
Did you make sure that you gave the same "50e-6" as sample time for all the blocks including "Digital Clock" block? "Digital Clock" has a default sample time of 1 sec. If it is not set to the base sample time, your application might terminate prematurely based on the end time of Simulation set in model.

Categorías

Más información sobre Deployment, Integration, and Supported Hardware en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by