Hello,
My Simulink model of an induction machine run about 2 second even if the simulation time is 20 sec. any idea on that?
The model is include of 3-phase to d-q model and then transforming to rotor reference model. the last step is deriving currents and applying the electrical torque and the mechanical torque has not been implemented yet. sot machine is working in no-load condition.
Regards,
0 comentarios
Respuesta aceptada
Andreas Goser
el 9 de Feb. de 2012
Please verify the scope setting: Parameters - Data History - Limit Data Point to last.
The default is it is checked and limited to 5000 points.