Borrar filtros
Borrar filtros

Simulink shows only the last 2 second of simulation time

7 visualizaciones (últimos 30 días)
Alzapoa
Alzapoa el 9 de Feb. de 2012
Editada: Matt J el 6 de Oct. de 2013
Hello,
My Simulink model of an induction machine run about 2 second even if the simulation time is 20 sec. any idea on that?
The model is include of 3-phase to d-q model and then transforming to rotor reference model. the last step is deriving currents and applying the electrical torque and the mechanical torque has not been implemented yet. sot machine is working in no-load condition.
Regards,

Respuesta aceptada

Andreas Goser
Andreas Goser el 9 de Feb. de 2012
Please verify the scope setting: Parameters - Data History - Limit Data Point to last.
The default is it is checked and limited to 5000 points.

Más respuestas (0)