Setting Time Tolerances & Simulink.sdi.report

4 visualizaciones (últimos 30 días)
Richard Hopple
Richard Hopple el 20 de Sept. de 2017
Comentada: Mike Crawford el 12 de Abr. de 2019
I'm trying to figure out how to set the new time tolerance via an API. I looked under the signalObj but that seems to have the relative and absolute tolerances but nothing related to time.
  1 comentario
Richard Hopple
Richard Hopple el 20 de Sept. de 2017
I realized I neglected to add this is under the simulation data inspector when you compare two runs.

Iniciar sesión para comentar.

Respuestas (1)

David Ding
David Ding el 28 de Sept. de 2017
Hi Richard,
I understand that there is current no corresponding property in the Simulink SDI API that accesses the time tolerance of a signal for comparison. Such property is accessible in the SDI UI but not programmatically.
We are considering adding a "Time Tolerance" property into our SDI API for R2018a. In the meantime, there is a workaround using Simulink Test to compare a signal with a specified baseline involving time tolerances. In the following documentation:
Please scroll down to the example:
"Add Baseline Criteria and Change Tolerance"
On the last line of the example code,
sc(1).AbsTol = 9;
Please change "AbsTol" to either "LaggingTol" or "LeadingTol" depending whether the time tolerance is leading or lagging.
All the best,
David
  2 comentarios
William R
William R el 24 de Ag. de 2018
You write that 'We are considering adding a "Time Tolerance" property into our SDI API for R2018a". What is the outcome of this consideration? Is it already added to 2018a or 2018b? I need this signal time tolerance and I think it is really a missing feature.
Mike Crawford
Mike Crawford el 12 de Abr. de 2019
In case you haven't seen yet, time tolerance was added in 2018A.

Iniciar sesión para comentar.

Etiquetas

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by