set initial value for a signal and then rewrite it

2 visualizaciones (últimos 30 días)
Peppe
Peppe el 27 de Sept. de 2017
Comentada: Peppe el 10 de Oct. de 2017
Hi, I have a loop in which an observer observe the states and then backward it to a controller. There need to be an initial value for one signal. That signal will start the simulations and gets other values in the loop. Does anyone know how to set the initial value for such system in Simulink?

Respuesta aceptada

Jyotish Robin
Jyotish Robin el 9 de Oct. de 2017
Editada: Jyotish Robin el 9 de Oct. de 2017
Hi!
As far as I understand you are looking for a way in which you can specify the initial value for a signal in a Simulink model.
Probably the IC block will fit your needs.
The IC block sets the initial condition of the signal at its input port, for example, the value of the signal at the simulation start time (t_start). The block does this by outputting the specified initial condition when you start the simulation, regardless of the actual value of the input signal. Thereafter, the block outputs the actual value of the input signal.
Hope this helps!
Regards,
Jyotish