Does the PowerGui Block, in case of choosing the continuous solver method, solely use a variable-step Simulink solver even if my configuration for the global simulink solver is a fixed-step type?
5 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Christian
el 15 de En. de 2018
The question is referring to the following statement which is mentioned in the documentation for the PowerGui Block: "Continuous, which uses a variable-step solver from Simulink®"
My Model Configuration and Topology:
Global simulink solver: fixed-step ode14x
Two Model parts using one PowerGui Block each:
- Discrete Referenced Model with fixed time step local Tustin/Backward Euler solver
- Continuous Subsystem which uses (and this is the question
The Referenced Model and the subsystem exchange simulink signals and collectively represent the parent model.
Thanks in advance! Kind regards. Christian
0 comentarios
Respuesta aceptada
Emmanouil Tzorakoleftherakis
el 24 de En. de 2018
Hi Christian,
From the link below, it is recommended that you implement fixed-step solvers by continuing to use a global variable-step solver and switching the physical networks within your model to local fixed-step solvers through each network.