            Hello every one, I'm an electrical engineering student, and I'm trying to modelling and simulating a hydroeletric power plant.l I'm new at matlab and simulink, so i'm having lot of doubts about that.
I projected a station just like that bellow:


After that, when i try to compilate the project, i got this error:

I really have no idea about how to fix it. Can some one please help me with this? Thank you all :)
0 comentarios
Respuesta aceptada
  Walter Roberson
      
      
 el 25 de Jun. de 2018
        You need to resolve the link into the bottom of the Local Load block, in order to provide a value for the VRated input.
You need to open the Machine Mechanical Power (SI) block and look at the parameter fElectrical0 which you will find that you have defined in terms of FRated, but you have not defined FRated
You need to open the Reactive Compensation block and look at the parameter C which you will find that you have defined in terms of reactiveCompensationCapacitance, but you have no defined reactiveCompensationCapacitance
See https://www.mathworks.com/help/simulink/ug/parameter-values-and-specification-methods.html for ways you can define those parameters.
2 comentarios
  Walter Roberson
      
      
 el 25 de Jun. de 2018
				You can try either of those recommended actions.
However, probably you will need to remove the algebraic loop. See https://blogs.mathworks.com/simulink/2015/07/18/why-you-should-never-break-an-algebraic-loop-with-with-a-memory-block/