what are the reasons for power flow is completed in very short period (less than 1 second) and the graph is not comming?
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
>> psat
< P S A T >
Copyright (C) 2002-2014 Federico Milano
Version 2.1.9
September 6, 2014
PSAT comes with ABSOLUTELY NO WARRANTY; type 'gnuwarranty' for details. This is free software, and you are welcome to redistribute it under certain conditions; type 'gnulicense' for details.
Host: Matlab 8.1.0.604 (R2013a) Session: 30-Sep-2018 10:55:41 Usage: Graphical User Interface Path: C:\Program Files\MATLAB\R2013a\toolbox\psat\tests
Error using load Unable to read MAT-file C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1.mdl: not a binary MAT-file. Try LOAD -ASCII to read as text.
Error in fm_set (line 348) load([pathname,file],'-mat')
Error while evaluating uicontrol Callback
Simulink Model Conversion Simulink File system1fault.mdl. Loading Simulink Model * * * Check model version and blocks ... * * All blocks belong to the PSAT-Simulink Library. * * * Statistics ... Connections: #9# Power Flow Components: #15# Faults & Breakers: #1# Machines: #3# * * * Definition of component data ... Data "Fault.con" Data "Bus.con" Data "Line.con" Data "PQ.con" Data "PV.con" Data "SW.con" Data "Syn.con" Data "Line.con" * * * Definition of system connections ... * * * Writing Data File Construction of Data File system1fault_mdl.m completed. Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" set
Newton-Raphson Method for Power Flow Computation Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" Voltage rate of Slack Bus #1 at Bus G1 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #1 at Bus G2 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #2 at Bus G3 BUS differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #1 at Bus LOAD BUS B differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #2 at Bus LOAD BUS C differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #3 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Tap ratio of transformer #7 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #8 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #9 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Voltage of Line #1 from bus BUS to bus BUS C differs more than 10% from the base defined at the connected bus BUS Voltage of Line #3 from bus BUS to bus BUS A differs more than 10% from the base defined at the connected bus BUS Voltage of Line #6 from bus BUS to bus BUS B differs more than 10% from the base defined at the connected bus BUS Voltage of Line #7 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #8 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #9 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage rate of Fault #1 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Voltage rate of Synchronous Machine #2 at Bus G1 BUS differs more than 10% from Bus voltage rate Writing file "fm_call" ... PF solver: Newton-Raphson method Single slack bus model Iteration = 1 Maximum Convergency Error = 1012.5951 Iteration = 2 Maximum Convergency Error = 2207.4126 Iteration = 3 Maximum Convergency Error = 1749160304.7746 Iteration = 4 Maximum Convergency Error = 134045474417.6818 Iteration = 5 Maximum Convergency Error = 1608111387.7758 The error is increasing too much. Convergence is likely not reachable. Initialization of Synchronous Machines completed. Power Flow completed in 1.082 s
Continuation Power Flow - Single Slack Bus Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)"
Corrector Method: Perpendicular Intersection Check Voltage Limits: No Check Generator Q Limits: No Check Flow Limits: No
* Max # of iters. at corrector step.
* Reduced Variable Increments in Corrector Step 0.5
Operands to the || and && operators must be convertible to logical scalar values.
Error in fm_cpf (line 551) if lambda > lambda_old && lambda < max(l_vect) && ~Hvdc.n
Error while evaluating uicontrol Callback
Dynamic components are not supported for static analysis
Continuation Power Flow - Single Slack Bus Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)"
Corrector Method: Perpendicular Intersection Check Voltage Limits: No Check Generator Q Limits: No Check Flow Limits: No
* Max # of iters. at corrector step.
* Reduced Variable Increments in Corrector Step 0.5
Operands to the || and && operators must be convertible to logical scalar values.
Error in fm_cpf (line 551) if lambda > lambda_old && lambda < max(l_vect) && ~Hvdc.n
Error while evaluating uicontrol Callback
Newton-Raphson Method for Power Flow Computation Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" Voltage rate of Slack Bus #1 at Bus G1 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #1 at Bus G2 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #2 at Bus G3 BUS differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #1 at Bus LOAD BUS B differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #2 at Bus LOAD BUS C differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #3 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Tap ratio of transformer #7 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #8 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #9 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Voltage of Line #1 from bus BUS to bus BUS C differs more than 10% from the base defined at the connected bus BUS Voltage of Line #3 from bus BUS to bus BUS A differs more than 10% from the base defined at the connected bus BUS Voltage of Line #6 from bus BUS to bus BUS B differs more than 10% from the base defined at the connected bus BUS Voltage of Line #7 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #8 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #9 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage rate of Fault #1 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Voltage rate of Synchronous Machine #2 at Bus G1 BUS differs more than 10% from Bus voltage rate Writing file "fm_call" ... PF solver: Newton-Raphson method Single slack bus model Iteration = 1 Maximum Convergency Error = 1012.2139 Iteration = 2 Maximum Convergency Error = 2440.9057 Iteration = 3 Maximum Convergency Error = 1007876111.3747 Iteration = 4 Maximum Convergency Error = 371974.8361 Iteration = 5 Maximum Convergency Error = 319025.6289 Iteration = 6 Maximum Convergency Error = 604865.7609 Iteration = 7 Maximum Convergency Error = 71178.6145 Iteration = 8 Maximum Convergency Error = 48631.3528 Iteration = 9 Maximum Convergency Error = 3519046.1394 The error is increasing too much. Convergence is likely not reachable. Initialization of Synchronous Machines completed. Power Flow completed in 0.754 s
Time domain simulation Trapezoidal integration method Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" No perturbation file set. * The option "Settings.forcepq" overwrites the option "Settings.pq2z". * All PQ loads will be forced to consume constant powers. Singularity likely. Simulation stopped at t = 0 s
Newton-Raphson Method for Power Flow Computation Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" Voltage rate of Slack Bus #1 at Bus G1 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #1 at Bus G2 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #2 at Bus G3 BUS differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #1 at Bus LOAD BUS B differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #2 at Bus LOAD BUS C differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #3 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Tap ratio of transformer #7 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #8 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #9 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Voltage of Line #1 from bus BUS to bus BUS C differs more than 10% from the base defined at the connected bus BUS Voltage of Line #3 from bus BUS to bus BUS A differs more than 10% from the base defined at the connected bus BUS Voltage of Line #6 from bus BUS to bus BUS B differs more than 10% from the base defined at the connected bus BUS Voltage of Line #7 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #8 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #9 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage rate of Fault #1 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Voltage rate of Synchronous Machine #2 at Bus G1 BUS differs more than 10% from Bus voltage rate Writing file "fm_call" ... PF solver: Newton-Raphson method Single slack bus model Iteration = 1 Maximum Convergency Error = 1012.2139 Iteration = 2 Maximum Convergency Error = 2440.9057 Iteration = 3 Maximum Convergency Error = 1007876111.3747 Iteration = 4 Maximum Convergency Error = 371974.8361 Iteration = 5 Maximum Convergency Error = 319025.6289 Iteration = 6 Maximum Convergency Error = 604865.7609 Iteration = 7 Maximum Convergency Error = 71178.6145 Iteration = 8 Maximum Convergency Error = 48631.3528 Iteration = 9 Maximum Convergency Error = 3519046.1394 The error is increasing too much. Convergence is likely not reachable. Initialization of Synchronous Machines completed. Power Flow completed in 0.448 s Plotting Utilities: No data available for plotting. Plotting Utilities: No data available for plotting. Plotting Utilities: No data available for plotting.
Error using load Unable to read MAT-file C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault.mdl: not a binary MAT-file. Try LOAD -ASCII to read as text.
Error in fm_set (line 348) load([pathname,file],'-mat')
Error while evaluating uicontrol Callback
Simulink Model Conversion Simulink File system1fault.mdl. Loading Simulink Model * * * Check model version and blocks ... * * All blocks belong to the PSAT-Simulink Library. * * * Statistics ... Connections: #9# Power Flow Components: #15# Faults & Breakers: #1# Machines: #3# * * * Definition of component data ... Data "Fault.con" Data "Bus.con" Data "Line.con" Data "PQ.con" Data "PV.con" Data "SW.con" Data "Syn.con" Data "Line.con" * * * Definition of system connections ... * * * Writing Data File Construction of Data File system1fault_mdl.m completed. Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" set Solve base case power flow...
Newton-Raphson Method for Power Flow Computation Voltage rate of Slack Bus #1 at Bus G1 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #1 at Bus G2 BUS differs more than 10% from Bus voltage rate Voltage rate of PV Bus #2 at Bus G3 BUS differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #1 at Bus LOAD BUS B differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #2 at Bus LOAD BUS C differs more than 10% from Bus voltage rate Voltage rate of PQ Bus #3 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Tap ratio of transformer #7 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #8 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Tap ratio of transformer #9 from bus BUS to bus BUS differs more than 10% from the bases defined at connected buses. Voltage of Line #1 from bus BUS to bus BUS C differs more than 10% from the base defined at the connected bus BUS Voltage of Line #3 from bus BUS to bus BUS A differs more than 10% from the base defined at the connected bus BUS Voltage of Line #6 from bus BUS to bus BUS B differs more than 10% from the base defined at the connected bus BUS Voltage of Line #7 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #8 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage of Line #9 from bus BUS to bus BUS differs more than 10% from the base defined at the connected bus BUS Voltage rate of Fault #1 at Bus LOAD BUS A differs more than 10% from Bus voltage rate Voltage rate of Synchronous Machine #2 at Bus G1 BUS differs more than 10% from Bus voltage rate PF solver: Newton-Raphson method Single slack bus model The error is increasing too much. Convergence is likely not reachable. Initialization of Synchronous Machines completed. Power Flow completed in 0.199 s
Time domain simulation Trapezoidal integration method Data file "C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1fault(mdl)" No perturbation file set. * The option "Settings.forcepq" overwrites the option "Settings.pq2z". * All PQ loads will be forced to consume constant powers. Singularity likely. Simulation stopped at t = 0 s
1 comentario
Walter Roberson
el 4 de Abr. de 2021
Error using load Unable to read MAT-file C:\Program Files\MATLAB\R2013a\toolbox\psat\tests\system1.mdl: not a binary MAT-file. Try LOAD -ASCII to read as text.
You cannot load() a .mdl file. .mdl files are structured text (but not XML)
Respuestas (1)
Ver también
Categorías
Más información sobre Event Functions en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!