Obtaining signal units post compilation

Hello, is it possible to obtain the signal units associated with a port, post compilation? I am trying to find a property similar to CompiledPortDataType, but for units. What would be the correct way to programmatically obtain the units associated with an arbitrary line once the model has been compiled?

 Respuesta aceptada

Fangjun Jiang
Fangjun Jiang el 20 de Nov. de 2018

1 voto

CompiledPortUnits
But according to R2018b document,
Simulink passes units through the following blocks that do not change data, known as noncomputation blocks
Simulink does not propagate units through blocks that produce new data as output.
So it is possible to specify the unit of a root level Inport block as "N", pass it through several levels of sub-system Inport (all specified as inherit) and then check the compiledportunits of the inner Inport block and it will return "N".
You can not expect the CompiledPortUnits of a Product block to be "N*m" by specifying the two inputs of the Product block to be "N" and "m".

1 comentario

sst
sst el 20 de Nov. de 2018
Thanks, that actually is exactly what I was looking for. Somehow this property didn't show up via tab completion for port handles, but it worked regardless.

Iniciar sesión para comentar.

Más respuestas (0)

Categorías

Más información sobre Simulink Functions en Centro de ayuda y File Exchange.

Productos

Versión

R2018a

Preguntada:

sst
el 20 de Nov. de 2018

Comentada:

sst
el 20 de Nov. de 2018

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by